The Core Facility

Document Actions


Endogenous Metabolites non-targeted profiling 


Primary metabolites
Secondary metabolites

The Pegasus III TOF mass spectrometer (LECO) offers acquisition of up to 500 spectra per second within mass range ~20 - 600 Da and automated peak deconvolution software for unbiased and high quality peak detection and chromatogram comparisons. We have equipped this instrument with robotic derivatization and exchange liner in order to diminish externally induced deviations by reaction times, matrix carryovers and analyte cross contaminations.

Click here to have a look at the list of compounds that we are able to identify.

The ACQUITY UPLC System designed to match the performance needs of WATERS column chemistries with robust hardware and easy-to-use software. With UPLC we have the ability to work more efficiently with higher speed, sensitivity and resolution at a much wider range of linear velocities, flow rates and backpressures to obtain superior results.

High speed acquisition offered by FINNIGAN LTQ allows to perform online fragmentation experiments in both positive and negative modes providing detected components with the valuable structural information.

 


Click here to redirect to bioinformatics/statistics analysis we offer on obtained results

We offer a system that combines mass spectrometric and biological metadata.
SetupX system enables entering biological metadata for steering laboratory
workflows by generating ‘classes’ that reflect experimental designs.
Acquired GC/TOF/MS data is forwarded to Bin Base.
BinBase database system provides automated metabolite annotation.

http://fiehnlab.ucdavis.edu/projects/binbase_setupx/


Typical UPLC-RP-MS chromatogram of Arabidopsis Thaliana leaf crude extract.

 



Exogenous Metabolites LC-MS profiling (Metabolic Biotransformations)


Normal phase and  reverse phase UPLC/ HPLC metabolite profiling and isolation.
Intelligent data acquisition with LightSight  2.0 on Q-Trap4000 LC-MS/MS system.
LTQ and Q-Trap4000 for MSn CID fragmentation.
LTQ-FT-ICR-MS for definitive metabolite identification by accurate
accurate masses and isotope signatures,
plus MassWorks™ with sCLIPS algorithm for accurate mass measurement data interpretation.
Access to NMR – 1D, 1H, 13C, 19F, 31P (up to 800MHz).
Access to NMR – 2D COSY, NOESY, 13C-1H correlation.

LightSight™ 2.0 (Applied Biosystems) Click here for technical note/tutorial.